Product Description

TECHNITHERM® is a totally CFC & HCFC FREE two component, 1:1 mix ratio rigid polyurethane foam which complies with the requirements of BS 7457:1994 for the stabilisation and thermal insulation of masonry cavity walls and holds an Agrément Board Certificate No: 97/3426. It is required that TECHNITHERM® is installed in accordance with BS 7456:1991 Code of Practice by BBA approved installers trained by Isothane Ltd technical staff.

Uses

TECHNITHERM® is used for the stabilisation of masonry cavity walls by strongly adhering the inner and outer leaves together and as such is a convenient and cost effective alternative to metal cavity tie replacement. In addition, as a consequence of the excellent thermal insulation properties of the foam, “U” values of 0.33 Wm²K are achieved in a 65mm cavity of standard construction, and 0.22 Wm²K in a 100mm cavity of standard construction. Even better values can be realised through choice of special blockwork, etc.

Equipment

TECHNITHERM® can be processed through any suitable mobile high pressure plural component polyurethane foam dispensing equipment. (e.g. Gusmer, Glas-Craft, Graco).

Reactivity Profile

Laboratory test results ( typical ) at 20ºC:-

Cream time: 13 - 18 seconds
Rise time: 155 ± 15 seconds
Free rise density: 32 ± 1 kg/m³

Storage, Handling and Personal Protection

The recommendations in our Safety Data Sheet for this product must be followed at all times. More general information is included in our publication “A Guide to the Safe Handling of Polyurethane Chemicals” and in the following Technical Data Sheets which are available on request:-

  • Fire safety when Storing, Handling and Installing Polyurethane Foam.
  • Decontamination of Isocyanates using Isothane Decontaminant.

Physical Properties

Property Value Method
*Thermal conductivity, aged, <80mm thick 0.028 W / mK BS EN ISO 13165
*Thermal conductivity, aged, 80-120mm thick 0.026 W / mK BS EN ISO 13165
*Thermal conductivity, aged, >120mm thick 0.025 W / mK BS EN ISO 13165
Compressive strength -   BS4370:Pt1
normal to major plane: ( 50mm cavity ) 210 kPa  
Shear strength -   BS4370:Pt2
parallel to major plane: ( 50mm cavity ) 241 kPa
Dimensional stability linear change at:    
24hrs @ -15ºC - 0.2 / 0 / 0.2%
( L / W / T )
BS4370:Pt1
24hrs @ +70ºC 0.3 / 0.4 / 0.1%
( L / W / T )
 
Water Vapour Permeability 5.9ng / (pa.sm) max BS4370:Pt2
parallel to foam thickness    
Closed Cell Content 90% BS4370:Pt2
* Burning Characteristics Less than 40mm BS4735
*Tensile Adhesion to Masonry:  
Aerated Concrete
51 kPa  
Brick
155 kPa BS4757
Breeze Block
166 kPa  
Appearance Uniform, fine cell structure BS4757
Density 42 Kg / m³ BS4757

*Tests carried out independently by UKAS Approved Laboratories.

Technitherm® System Components:-

Resin SG @ 20º C 1.15
Resin Viscosity @ 20º C 400cps
Iso SG @ 20º C 1.24
Iso Viscosity @ 20º C 350cps
Ozone Depletion Potential ( ODP ) ZERO